3-18
3.12 FIBER OPTIC CABLE CONNECTIONS
This system normally operates as a Class I Laser Product (no
hazard), however during servicing operations, when optical
connectors are being connected, disconnected, or handled
without dust covers, it is possible to be exposed to Class IIIB
laser radiation which can cause eye damage.
Fiber optic connectors are delicate and can be damaged eas-
ily by dirt or debris on the end of the connector. Keep fiber
optic connectors free of dust and debris by cleaning the con
-
nector before and after use. Carefully clean the fiber optic
connector and cable ends with a cotton swab dipped in alco
-
hol or an alcohol wipe. Keep safety cap on connectors when
not in use.
The Alcatel 2 or 4 fiber management panel (PN 3EM09257AB) and 2x4 fiber management
panel (PN 3EM09257AA) connections are described. For other fiber management equip
-
ment, refer to the manufacturers instructions. See Figure 3 - 11 and Figure 3 - 12 for typical
connections. Refer to Table 3 - 10 for recommended fiber optic jumpers.
DANGER
Possibility of
Injury
to Personnel
WARNING
Possibility of
Damage
to Equipment