3.18.1 MCS-11 Master (J307)
If the radio is provisioned
Repeater
, port 2 on the controller, that con-
nects to J307, is disabled. At a repeater, you can use J310 in lieu of
J307 for connecting the TSM polling engine to the radio.
MCS-11 connector J307 is used to connect to a TSM (-2500, -3500, or -8000) polling engine
at a master terminal.
Recommended connectorized cable assembly – PN 695-4126-007/009/012 (26 AWG 8 pair
shielded, jacketed cable). See
Figure 3 - 27 for shelf connector location and pinout. Refer to
Table 3 - 18 for mating cable pinout and color code. See Figure 3 - 28 for typical connection
scheme.
Figure 3 - 27 MCS-11 Master Connector (J307) Location and Pinout
Note
J315
J301
J313
J308 J309
J310 J312
J318
J305
J316 J317 J302
XMT DATA +
J307
FRONT VIEW
RTN CLK +
XMT CLK +
RCV DATA +
RCV CLK +
RCV CLK –
RCV DATA
XMT CLK –
RTN CLK –
XMT DATA
81
15 9
J307 J312
LMW-7052F
07/23/02
J310

Table of Contents