2-21
DX-35R-2 (DX-35R-1 is not shown).
Both the Ethernet and optical ports can be connected for backup protection. Only
one port is active. When both are connected, the optical port has priority over the
Ethernet port and will remain the active port unless a failure occurs.
Figure 2-12 DX-35R/S ETH I/O Interface Controls and Indicators
Note
ETH-1068
07/23/07
Red LED indicates module failure.
Green LED indicates XMT and/or RCV circuits are passing data.
Green LED indicates DS1 in service.
Yellow LED indicates loss of DS1 radio XMT imput signal, radio
RCV DS1 output failure, or AIS on DS1 RCVR output.
Green LED when on solid, indicates an input link is established.
When flashing, indicates data on input. When off, indicates no link.
Yellow LED indicates XMT or RCV Ethernet degrade.
Electrical connector RJ-45
Green LED when on solid, indicates output link is established. When
flashing, indicates data activity on output. When off, indicates no link.