Using WebView Quick Steps for Setting Up WebView
OmniSwitch AOS Release 6 Switch Management Guide July 2010 page 12-5
Quick Steps for Setting Up WebView
1 Make sure you have an Ethernet connection to the switch.
2 Configure switch management for HTTP using the aaa authentication command. Enter the command,
the port type that you are authenticating (http), and the name of the LDAP, RADIUS, ACE, or local
server that is being used for authentication. For example, to configure switch management for HTTP using
the “local” authentication server you would enter:
-> aaa authentication http local
3 Open a web browser.
4 Enter the IP address of the switch you want to access in the Address field of the browser and press
Enter. The WebView login screen appears.
5 Enter the appropriate user ID and password (the initial user name is admin and the initial password is
switch). After successful login, the Chassis Management Home Page appears.
WebView Overview
The following sections provide an overview of WebView page layouts. For information on configuring
the switch with WebView, see page 12-8.
WebView Page Layout
As shown below, each WebView page is divided into four areas:
Banner—Used to access global options (e.g., global help, telnet, and log out). An icon is also
displayed in this area to indicate the current directory (Certified or Working).
Toolbar—Used to access WebView features.
Feature Options—Used to access specific configuration options for each feature (displayed in drop-
down menus at the top of the page).
View/Configuration Area—Used to view/configure a feature.