5. Enter the password pbxk1064.
6. The OMC-Software Download window opens. This window has several areas:
A parameter setting area:
Select the directory containing the descriptor file for the new software release. By default this
file is in the BOOT directory.
Use the Delivery file browse button.
Select the country for the new software release.
Use the ...Delivery drop down menu in the Country & Supplier... area. As an indication, the
PBX field gives the country of the currently used software release.
Download all the files (by checking the Download all files box) or just those whose Action
field contains the value Install.
Save the data.
If the Data saving box is checked, the system automatically saves and restores the data after
having swapped over to the new software release.
If the Data saving box is not checked, you must use OMC to save the data before starting
the download. Restore this data after the download/swap is complete.
Select the ACD/MLAA/SCR service box to download the ACD (Automatic Call Distribution)
and the MLAA (Multiple Automated Attendant) and the SCR (Smart Call routing) optional
components.
Download the files needed for the Voice over IP features.
Depending on customer needs, check the My IC Phone box and/or 4135 IP Conference
Phone box (the Voice over IP services box is automatically checked).
Select the language of the voice guides to download.
Click on the Languages button to access the Languages Download window.
Define a time zone by selecting a city and country.
Click on the Time Zone button to access the Time Zones Download window.
Define the software swap mode.
In the Software Exchange area, there are two possible choices:
Click on the After OMC disconnect button to swap immediately. The swap starts when you
quit the downloading application.
Click on the Date button and indicate the required date and time for a delayed swap.
Remark:
If you select immediate switching, it will take effect as soon as you quit the download application.
A read only zone
The Downloadable Item area allows you to see the different versions of the applications.
The Action column lists the files to download.
The bottom part of the window shows download progress. Each downloading and
acknowledgement action produces a message.
7. Click Start to start downloading.
6.2.4.2 Downloading software for OXO Connect Compact platform (and OXO Connect Small,
Medium, Large platforms delivered in stock mode)
Remark:
Because the OXO Connect Compact platform does not use internal backup batteries like the other OXO Connect
Small, Medium, Large platforms, it is important not to cut off the cabinet's main power supply during software
download. Any power shut down during the BIOS downloading will damage the PowerCPU EE.