WARNING
B 00
3 / 4
Alcatel Vacuum Technology France --- IPUP A100 Instruction manual
Safety instructions
l Alcatel has no control over the types of gases passing through this
pump. Frequently, process gases are toxic, flammable, corrosive,
explosive or otherwise reactive. Since these gases can cause
serious injury or death, it is very important to plumb the exhaust of
the pump to the facilitys hazardous gas exhaust system which
incorporates appropriate filters, scrubbers, etc., to insure that the
exhaust meets all air regulations.
l Check that pump is correctly connected to the equipment
(see B 50).
Safety interlock
The pump motor is protected against overload through the
drive start/stop and enable control circuitry of the variable
speed controller. The drive start/stop includes solid state
components. If hazards due to accidental contact with
moving machinery or unintentional flow or liquid, gas or
solids exist, an additional hardwired stop circuit is required
to remove AC input power to the drive.
This interlock must never be overridden during installation,
use or maintenance.
Once activated power will be switch off and the pump will be
putinasafecondition.Whenafaultoccurs,thecausemustbe
corrected before the fault can be cleared. It is required to
switch power off and on to clear the fault.