Alcatel Vacuum Technology France --- IPUP A100 Instruction manual
Monitoring system function table
IPUP A100P version
ACCESS TO PARAMETER
SETTINGS
Access the parameters by validating the access code (see C 30).
DEFINITION MENU
SET
ENTER ENTER
ENTER
Initial
configuration
LANGUAGE FRENCH/ENGLISH All the menus are in the selected language. English
N
ITION
SYSTEM
SELECT
A 100L
A 100P
Select the pump type. A 100P
D
EFI
N
POWER
START
ENABLED
DISABLED
Allows automaticpump start when poweredON
(control remote DISABLED only) (see C 10).
DISABLED
D
E
CONTROL
REMOTE
ENABLED
DISABLED
Allows pump command through SPI
connector (see C 10).
ENABLED
PURGE
COMMAND
ENABLED
DISABLED
Allows independant purge control at pump
start---up. The purge flow is controlled by the
PURGE control key or pump start---up con-
trolled.
DISABLED
INTERN. T°
OPTION
ENABLE
DISABLED
Temperature regulation validation. ENABLED
BUZZER ENABLED
DISABLED
Controls buzzer ON/OFF in case of a fault.
Buzzer stop by pressing ENTER.
ENABLED
Do not set a P pump to an L pump configuration.
Line N2 will not be supplied and the internal temperature
regulation will be false.
This will quickly wear down the pumps parts.
Select the pump for the process it is being used in.
G
B
0
0
5
3
7