D 80
2 / 2
Alcatel Vacuum Technology France --- IPUP A100 Instruction manual
Fault message display --- Facilities
problem
IPUP A100 WITH HAND HELD
DISPLAY MODULE
Pump is running and displays a
warning
NO
Motor temperature is > 50 °C
Warning
W10: MOTOR TEMP.
INCIDENT CAUSE TROUBLESHOOTING
Other problem
l Call your Alcatel Service
Representative.
l Check the water supply.
Pump is stopped and displays a
hazard
Hazard
D10: MOTOR TEMP.
INCIDENT CAUSE TROUBLESHOOTING
NO
Motor temperature is > 75°C
l Check the water supply.
Wait for pump to cool.
Other problem
l Call your Alcatel Service
Representative.