Index-2
PowerFlex 4M Adjustable Frequency Drive FRN 1.xx - 2.xx User Manual
Publication 22F-UM001D-EN-E
G
General Precautions, P-3
Ground Fault, 4-3
Grounding
Filter, 1-6
General, 1-5
H
Heatsink OvrTmp Fault, 4-3
HW OverCurrent Fault, 4-3
I
I/O
Wiring, 1-13
Wiring Examples, 1-15, 1-18
I/O Board Fail Fault, 4-4
Input Contactor, 1-12
Input Fusing, 1-7
Input Potentiometer, 1-15
Input Power Conditioning, 1-4
Installation, 1-1
Integral Keypad, 2-3
Interference, EMC/RFI, 1-21
K
Keypad, 2-3
L
LEDs, 2-3
M
Minimum Clearances, 1-2
Motor Cable Length, 1-10
Motor Overload Fault, 4-3
Motor Stalled Fault, 4-3
motor starter, 1-7
Mounting Options and Clearances,
1-2
MOVs, 1-3
O
Opening the Cover, 1-1
Operating Temperatures, 1-2
Operator Interface, 2-3
OverVoltage Fault, 4-3
P
Parameter
Descriptions, 3-1
Types, 3-1
Viewing and Editing, 2-4
Parameter Checksum Fault, 4-4
Parameter Cross Reference
by Name, 3-31
Parameters
Advanced Program Group, 3-19
Communications Group, 3-17
Display Group, 3-3
Program Group, 3-8
Terminal Block Group, 3-13
PE Ground, 1-5
Phase Short Fault, 4-4
Phase to Ground Fault, 4-4
Potentiometer, Wiring, 1-15
Power Cables/Wiring, 1-9
Power Conditioning, Input, 1-4
Power Loss Fault, 4-3
Power Unit Fault, 4-4
Powering Up the Drive, 2-1, 2-2
Precautions, General, P-3
Product Selection, B-1
Program Group Parameters, 3-8
Programming, 3-1
PTC Analog Input Wiring, 1-15
R
Ratings, A-1
Reflective Wave Protection, 1-10
Removing Cover, 1-1
Repeated Start/Stop, 1-12
Repeated Start/Stop Precautions,
1-12
RFI, see
EMC/RFI
RWR (Reflective Wave Reducer),
1-10
S
Safety Ground, 1-5
Shielded Power Cables, 1-10
Short Circuit Protection, 1-7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 4M and is the answer not in the manual?

Allen-Bradley PowerFlex 4M Specifications

General IconGeneral
Input Voltage200…240V AC, 380…480V AC, 500…600V AC
Output Voltage0-Input Voltage
Control MethodSensorless Vector
CommunicationsRS-485
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
EnclosureIP20
Operating Temperature-10°C to 50°C
Storage Temperature-40°C to 70°C
Humidity5-95% (non-condensing)
DimensionsVaries by model
WeightVaries by model