EasyManua.ls Logo

Allen-Bradley PowerFlex 750 Series - Page 55

Allen-Bradley PowerFlex 750 Series
548 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rockwell Automation Publication 750-PM001N-EN-P - February 2017 55
Drive Port 0 Parameters Chapter 3
MOTOR CONTROL
Mtr Ctrl Options
1659 IPM Tran Angle
IPM Transition Angle
Difference Threshold between High and Low angle control to allow transition.
Note: This parameter is not used by Frame 8 drives and larger.
Units:
Default:
Min/Max:
Cnts
100.0
5.0 / 500.0
RW Real
1660 IPM Stc OfsTst K
IPM Static Offset Test Constant
Reduction factor for Static Offset test pulses.
Note: This parameter is not used by Frame 8 drives and larger.
Default:
Min/Max:
1.00
0.10 / 9.00
RW Real
1661 IPM Lq Cmd BW
IPM Lq Command Bandwidth
IqFddk Filter Bandwidth (BW) used to select the Active Lq for the IPM control.
Note: This parameter is not used by Frame 8 drives and larger.
Units:
Default:
Min/Max:
R/S
10.0
1.0 / 999.9
RW Real
File
Group
No. Display Name
Full Name
Description
Values
Read-Write
Data Type

Table of Contents

Other manuals for Allen-Bradley PowerFlex 750 Series

Related product manuals