Chapter 3
Interpret the Attribute Tables
126 Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
ID Access
Rule
Attribute B E F P V T Conditional Implementation
570 Set Frequency Control Method
- R - - - O-Enum
128 = Fan/Pump Volts/Hertz (Y) 129 = Sensorless Vector (Y)
130 = Sensorless Vector Economy (N)
498 Set Friction Compensation Sliding
- - Y Y Y4
499 Set Friction Compensation Static
- - Y Y4 Y4
500 Set Friction Compensation Viscous
- - Y Y Y4
826/421 Set Friction Compensation Window
- - Y - -
981/243 Get Guard Faults
- Y Y Y Y
980/242 Get Guard Status
- Y Y Y Y
280 Set Home Torque Threshold
- - N N - Vxx
281 Set Home Torque Time
- - N N - Vxx
1349 Set Induction Motor Magnetization Reactance
- N N N N Ind Motor only
1352 Set Induction Motor Rated Slip Speed
- Y N N N Ind Motor only
1351 Set Induction Motor Rotor Leakage Reactance
- Y Y Y Y Ind Motor only, V26/V27
1350 Set Induction Motor Rotor Resistance
- N N N N Ind Motor only
1348 Set Induction Motor Stator Leakage Reactance
- Y Y Y Y Ind Motor only, V26/V27
647 Set Inverter Overload Action
- Y Y Y Y O-Enum
1 = Current Foldback (Y) 128 = Reduce PWM Rate (N) 129 =
PWM Foldback (N)
699 Set Inverter Thermal Overload User Limit
- Y Y Y Y
1338 Set Linear Motor Damping Coefficient
- N N N N Linear Motor only
2313 Set Linear Motor Integral Limit Switch
- N N N N Linear Motor only
1336 Set Linear Motor Mass
- N Y Y Y Linear Motor only
1337 Set Linear Motor Max Speed
- N Y Y Y Linear Motor only
801 Get Load Observer Acceleration Estimate
- - Y Y Y
806 Set Load Observer Bandwidth
- - Y Y Y
805 Set Load Observer Configuration
- - Y Y Y O-Enum
1 = Load Observer Only (Y)
2 = Load Observer with Velocity Estimate (Y) 3 = Velocity
Estimate Only (Y)
4 = Acceleration Feedback (N)
809 Set Load Observer Feedback Gain
- - Y Y Y
807 Set Load Observer Integrator Bandwidth
- - Y Y Y
802 Get Load Observer Torque Estimate
- - Y Y Y
1370 Set Load Type
N N N N N DScale
750 Set Local Control N N N N N N O-Enum
1 = Conditionally Allowed (N) 2 = Allowed (N)
614 Set Mechanical Brake Control
- Y Y Y Y
616 Set Mechanical Brake Engage Delay
- Y Y Y Y
615 Set Mechanical Brake Release Delay
- Y Y Y Y
45 Set Motion Scaling Configuration
R R R R R O-Enum
1 = Drive Scaling (N)

Table of Contents

Other manuals for Allen-Bradley PowerFlex 755

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 755 and is the answer not in the manual?

Allen-Bradley PowerFlex 755 Specifications

General IconGeneral
CategoryAC Drive
Amperage2.2…1470 A
Output Voltage0 to Input Voltage
Output Current2.2…1470 A
EnclosureIP20, IP30, IP54
CommunicationsEtherNet/IP, ControlNet, DeviceNet
I/ODigital, Analog, Encoder, Relay
SafetySafe Speed Monitor
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Short Circuit, Ground Fault, Overtemperature
Operating Temperature-10°C to 50°C (14°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5…95% noncondensing
AltitudeUp to 1000m (3300ft) without derating
Voltage200-240V AC, 380-480V AC, 500-600V AC, 690V AC
Input Voltage200-240V AC, 380-480V AC, 500-600V AC, 690V AC
Control MethodSensorless Vector