EasyManua.ls Logo

Alliance Laundry Systems WF065B - Water Connection Requirements

Alliance Laundry Systems WF065B
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Water Connection Requirements
NOTE: Read Important Safety Instructions first. For in-
stallations in Europe, the machine should not operate
and used without this cover in case the hot water sup-
ply temperature is higher than 65°C. Refer to Figure 23
and Figure 24 .
NOTE: Read Important Safety Instructions first.
All intake connections to the machine are to be fitted with man-
ual shut-of
f valves and filters, to facilitate installation and servic-
ing.
In case it is necessary to disconnect the hot water hose from the
washer, isolate the hot water hose from the hot water supply and
wait sufficient time to allow to cooldown the water temperature
and connection hose. Then turn the connection nut slowly loose
until water starts dripping. Wait until dripping stops, then discon-
nect further.
The washer has been designed with a built-in "AB" airgap system
according to EN1717. Nevertheless, when potable water will be
connected to the washer, a local compliant double check valve or
some other no less effective device providing backflow preven-
tion protection to at least fluid category 3 shall be fitted at the
point of connections between the water supply and the washer.
To comply with UK water regulations a WRAS or NSF Reg 4 or
KiwaUK Reg 4 compliant double check valves must be used. Re-
fer to Figure 25
To comply with the Plumbing Code of Australia regulations
accordance to standard WMTS-101 an approved dual
check valve backflow prevention device with the watermark must
be fitted at the point of connection between the supply and the fit-
ting. Refer to Figure 25
Models manufactured through April, 2017
CHM2503N_SVG
1 2
NOTE: North American Models: Water inlet hose with
notches should be connected to the water supply
faucet, while the side of the water inlet hose without
notches should be connected to the water inlet
valves.
1. Water inlet valve connection (hose connection without
notch)
2. Water supply faucet connection (hose connection with
notch)
Figure 21
Models manufactured starting May, 2017
C-CZW2N
1
2
3
4
NOTE: North American Models: Install threaded re-
duction pieces together with sealant on all inlet
valves. The filling hose end piece with an internal fil-
ter must be connected to the water inlet tap. The
second end of the hose must be connected to a re-
duction piece.
1. Hose
2. Reduction
3. Seal
4. Valve
Figure 22
NOTE: Models outside of North America: For 6.5 kg / 14
lb. / 65 L,
7.5 kg / 20 lb. / , 10.5 kg / 25 lb. / 105 L, 13.5
kg / 30 lb. / 135 L, 18 kg / 40 lb. / 180 L and 24 kg / 55
lb. / 240 L Models, to connect cold water, use a hose
with plastic elbow. To connect hot water, use a hose
with metal elbow.
Do not re-use water hoses; only use new water hoses.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
45 Part No. D2418ENR6