General Information
This information is to be used when installing gas
tumble dryers in countries and/or on gases different
than the machine’s factory configuration. Tumble
Dryers are supplied from the factory for operation on
Natural Gas 1,000 Btu/cu. ft. (8,914 kcal/m
3
), or L.P.
Gas 2,500 Btu/cu. ft. (22,250 kcal/m
3
), in the
countries of GB/IE/PT/ES/IT/GR/LU/CH/BE. To
install machines in any other country, or on any other
gas, requires some level of modification.
Machines are built in two different configurations:
Natural Gas – regulated/governor
Liquefied Petroleum (L.P.) Gas – not regulated/
no governor
Serial plates supplied from the factory are configured
for GB/IE/PT/ES/IT/GR/LU/CH/BE. These
instructions pertain to the situations when the country
of use or gas supply is different than that on the serial
plate.
These instructions are only valid if the following
country code is on the appliance: GB/IE/PT/ES/IT/
GR/LU/CH/BE. If this code is not present on the
appliance, it is necessary to refer to the technical
instructions which will provide the necessary
information concerning the modification of the
appliance to the condition of use for the country.
Before installation, check that the local distribution
conditions, nature of gas and pressure, and the
adjustment of the appliance are compatible.
Table 1 describes the different gases that are available
in different CE countries, and how the machines need
to be configured to operate with those gases. In the
CE, there are Natural Gas configurations that do not
allow for machine regulation and L.P. Gas
configurations that must be regulated. For L.P. Gas,
third family B/P at 50 mbar (5 kPa), order Regulated
Natural Gas machines and convert according to
Table 1.

Table of Contents

Other manuals for ALLIANCE 030 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ALLIANCE 030 Series and is the answer not in the manual?

ALLIANCE 030 Series Specifications

General IconGeneral
BrandALLIANCE
Model030 Series
CategoryDryer
LanguageEnglish

Related product manuals