Installation/Operation/Maintenance
www.alliancelaundry.com
Tumble Dryers
50 Pound (22.7 Kilogram) Capacity
75 Pound (34 Kilogram) Capacity
Starting Serial No. 0904004427
Refer to Page 6 for Model Identification
TMB1277
Part No. 70457901ENR7
September 2013
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
TMB1277C

Table of Contents

Questions and Answers

  • M
    marissacoxAug 9, 2025
    What to do if spark on, but no flame in ALLIANCE Dryer?
    • A
      amandabenderAug 9, 2025
      If you observe a spark but no flame in your ALLIANCE Dryer, try the following: * First, verify that the gas supply is turned on. * Next, check for 24 VAC at the gas valve. * If these steps don't resolve the issue, there may be a bad control. In this case, check the voltage between the gas valve terminal MV and GND on the control.
  • G
    Gregory ShawAug 13, 2025
    What to do if valve on, but no spark during TFI in ALLIANCE CA050L?
    • R
      robinsonlaurenAug 14, 2025
      If the valve is on but there is no spark during TFI (Trial For Ignition) in your ALLIANCE Dryer, consider these possible solutions: 1. Check for a shorted electrode. 2. Ensure the spark gap is correctly set between .094 and .156 inch. 3. Inspect the high voltage cable for faults or poor connections. 4. It is also possible that there is a control failure.
  • S
    Scott WallaceAug 19, 2025
    Why is ALLIANCE Dryer control in lockout mode?
    • C
      Cameron LongAug 19, 2025
      If the control in your ALLIANCE Dryer is in lockout mode (70458701 Control Only), a manual reset of the control is needed. You can reset it by pushing the red lockout button or by using the front end control.
  • L
    Linda MillerAug 25, 2025
    What to do if thermostat on, but there is no spark or valve in ALLIANCE CA050L Dryer?
    • J
      James Dudley Jr.Aug 25, 2025
      If the thermostat is on but there is no spark or valve activity in your ALLIANCE Dryer, verify that the cable connects to the control and electrode and that voltage is present at the gas valve. Also, check the red LED for steady on or flashing codes, as it may indicate a bad control.
  • L
    lindafriedmanAug 29, 2025
    How to fix reset failure in ALLIANCE CA050L?
    • L
      leechristopherAug 29, 2025
      If you're experiencing a reset failure with your ALLIANCE Dryer, it might be because the reset switch was pressed for too long. Try resetting it again. If the issue persists, the reset switch might be shorted and need replacement.
  • E
    Emily KimSep 3, 2025
    What to do if ALLIANCE CA050L Dryer control does not start and green LED is off?
    • J
      Jesse SantiagoSep 3, 2025
      If the control of your ALLIANCE Dryer does not start and the green LED is off, ensure that there is 24 VAC present between 24V and ground (on 70458701 control only). If not, refer to the machine schematic. Also, check for 24 VAC between TH and ground; if absent, consult the machine schematic.