10. Wipe out the cylinder using an all-purpose
cleaner or detergent and water solution. Refer to
Figure 14.
IMPORTANT: The use of chlorine bleach for
removing any discoloration should be avoided
because bleach could damage the finish.
Figure 14
If the tumble dryer does not meet ANY of the listed
requirements, remove tumble dryer from use. Refer to
Removing Tumble Dryer from Service section.
Required for CE Models Only
Once machine is installed, please be sure to complete
the following items:
Review and verify machine operation with
customer.
Leave all literature and a signed Declaration of
Conformity with customer.
Review machine warranty information with
customer.
Apply warning sticker on front panel of machine,
in language appropriate to country of sale
(included in literature packet).
Installing CE Gas Drying Tumble
Dryer
General Information
This information is to be used when installing gas
tumble dryers in countries and/or on gases different
than the machine’s factory configuration. Tumble
Dryers are supplied from the factory for operation on
Natural Gas 1000 Btu/cu. ft. (8914 kcal/m
3
), or L.P.
Gas 2500 Btu/cu. ft. (22,250 kcal/m
3
), in the countries
of GB/IE/PT/ES/IT/GR/LU/CH/BE. To install
machines in any other country, or on any other gas,
requires some level of modification.
Machines are built in two different configurations:
Natural Gas – regulated/governor
Liquefied Petroleum (L.P.) Gas – not regulated/
no governor
For converting models from Natural Gas to L.P. Gas:
050 series – M4544P3
075 series – M4545P3
Serial plates supplied from the factory are configured
for GB/IE/PT/ES/IT/GR/LU/CH/BE. These
instructions pertain to the situations when the country
of use or gas supply is different than that on the serial
plate.
These instructions are only valid if the following
country code is on the appliance: GB/IE/PT/ES/IT/
GR/LU/CH/BE. If this code is not present on the
appliance, it is necessary to refer to the technical
instructions which will provide the necessary
information concerning the modification of the
appliance to the condition of use for the country.
Before installation, check that the local distribution
conditions, nature of gas and pressure, and the
adjustment of the appliance are compatible.
Table 1 describes the different gases that are available
in different CE countries, and how the machines need
to be configured to operate with those gases. In the
CE, there are Natural Gas configurations that do not
allow for machine regulation and L.P. Gas
configurations that must be regulated. For L.P. Gas,
third family B/P at 50 mbar (5 kPa), order Regulated
Natural Gas machines and convert according to
Table 1 .