Electrical Requirements
70457901ENR7
50
050 and 075 Series Electric Models
Serial Plate Rating
Terminal Block
Connections Required
Serial Plate Amps Recommended Circuit
Nonreversing Reversing
Breaker
Rating
Wire Size
AWG (mm
2
)
240V/50Hz/1ph
(050 Series only)
L1, Neutral and Ground 93 95 125A – 1 pole 1 (35)
200-208V/60Hz/3ph
L1, L2, L3 and ground 89 88 125A – 3 pole 1 (35)
200V/50Hz/3ph
L1, L2, L3 and ground 84 85 125A – 3 pole 1 (35)
230V/50Hz/3ph
L1, L2, L3 and ground 73 75 100A – 3 pole 3 (26.7)
240V/50Hz/3ph
L1, L2, L3 and ground 79 78 100A – 3 pole 3 (26.7)
240V/60Hz/3ph
L1, L2, L3 and ground 79 78 100A – 3 pole 3 (26.7)
380V/50 or 60Hz/3ph
L1, L2, L3 and ground 47 48 60A – 3 pole 6 (16)
400-415V/50Hz/3ph
L1, L2, L3 and ground 43 44 60A – 3 pole 6 (16)
440V/60Hz/3ph
L1, L2, L3 and ground 41 41 51A – 3 pole 6 (16)
480V/60Hz/3ph
L1, L2, L3 and ground 38 38 50A – 3 pole 6 (16)
Table 10

Table of Contents