Operating Instructions
70457901ENR7
64
To Program a Short Test Cycle:
1. Unplug machine power cord.
2. Write down machine control dip switch settings,
then set them all to the off position. Refer to
Figure 41.
3. Plug machine in and start a cycle.
NOTE: With all control dip switches off, the total
cycle time will be 2 minutes long (1 minute of heat
and 1 minute of cool down).
4. Once all testing is complete, unplug machine and
re-set dip switches to their original settings.
5. Plug machine in.
Figure 41
Error Codes
TMB2216N
1 2 3 4 5 6 7 8O
N
1
2345
6
78
Display Definition Corrective Action
AF (flashing)
Airflow switch opened/closed 5 or more
times in a running cycle.
Check airflow switch. Replace if inoperative.