34 x900 Series Switch and SwitchBlade
®
x908
C613-03092-00 REV J
Troubleshooting Cables
Cable test The virtual cable test facility diagnoses cable faults and the approximate
distance to them on Gigabit Ethernet RJ-45 ports for the following switches
running the AlliedWare operating system:
AT-9924T
x900-24XT
x900-24XT-N
x900-24XS
See “Test Facility” on page 57 for more information or the Test Facility chapter
in the AlliedWare
®
Operating System Software Reference. Not all copper SFPs
support this feature; however, those listed in
“SFP Ports” on page 20 do
support it.
The virtual cable test facility is not supported in the AlliedWare Plus operating
system.
Cable lengths Approximate cable lengths are reported for gigabit Ethernet RJ-45 ports on the
following switches running the AlliedWare operating system:
AT-9924T
x900-24XT
x900-24XT-N
x900-24XS
Cable length is reported after the link is established. To check the length, use
the show switch port command described in the Switching chapter in the
AlliedWare
®
Operating System Software Reference. The Cable Length parameter in
the output of this command can be one of the following values:
<50m
50–80m
80–110m
110–140m
>140m
- (either the port link is down, or the port is operating at 10 Mbps or
100
Mbps)
Cable length reporting is not supported in the AlliedWare Plus operating
system.

Table of Contents

Other manuals for Allied Telesis AT-9924T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AT-9924T and is the answer not in the manual?

Allied Telesis AT-9924T Specifications

General IconGeneral
BrandAllied Telesis
ModelAT-9924T
CategorySwitch
LanguageEnglish

Related product manuals