Chapter 4 Parameter Index
54
P2: Auxiliary run
Function
code
Parameter name LCD display Setting range
Factory
setting
Mod.
MODBU
S address
P2.00 Jog frequency Jog frequency
0.10Hz~upper limit
frequency
5.00Hz ○ 0300
P2.01
Jog acceleration
time
Jog
acceleration
time
Power ≤ 132kW
0.1~3600s
Power ≥ 160kW
1.0~3600s
22kW and
below:
6.0s
Others:
20.0s
○ 0301
P2.02
Jog deceleration
time
Jog
deceleration
time
Power ≤ 132kW
0.0~3600s
Power ≥ 160kW
0, 1.0~3600s
Note: If the deceleration
time is 0, stop in the
mode of free stopping at
stop in inching running
22kW and
below:
6.0s
Others:
20.0s
○ 0302
P2.03
Time of switching
between positive
and negative
rotation
Time of
switching
between
positive and
negative
rotation
0.0~3600.0s 0.0s ○ 0303
P2.04
Lower limit
frequency handling
mode
Lower limit
mode
0: Running at lower
limit frequency
1: Running at 0
frequency
2: Stopping
3: Reserve
0 × 0304
P2.05
Frequency
deviation setting
Frequency
deviation
0.00~2.50Hz 0.10Hz ○ 0305
P2.06
Carrier frequency
adjustment
selection
Carrier
frequency
adjustment
selection
0: No automatic
adjustment
1: Depending on the
load,
The inverter
automatically adjust
the temperature
It is the upper limit of
carrier frequency in
vector control mode or
when there is no
automatic adjustment
1 ○ 0306
P2.07
Upper limit of
carrier frequency
Upper limit of
carrier
frequency
Depend on model
Depend on
model
× 0307
P2.08
Lower limit of
carrier frequency
Lower limit of
carrier
frequency
1.0~P2.07 1.0 kHz × 0308
P2.09
Hopping frequency
1
Hopping
frequency 1
0.00-maximum
frequency
0.00Hz × 0309
P2.10
Hopping frequency
2
Hopping
frequency 2
0.00-maximum
frequency
0.00Hz × 030A
P2.11
Hopping frequency
3
Hopping
frequency 3
0.00-maximum
frequency
0.00Hz × 030B