Chapter 4 Parameter Index
56
Function
code
Parameter name LCD display Setting range
Factory
setting
Mod.
MODBU
S address
P2.36 Cooling fan control Fan control
0: Automatic mode
1: Running after power
on
0 × 0324
P2.37
Wiring direction of
motor
Wiring
direction of
motor
0: Positive sequence
1: Inverted sequence
0 × 0325
P2.38
Anti-reverse
selection
Anti-reverse
selection
0: Reverse rotation is
activated
1: Reverse rotation is
disabled
0 × 0326
P2.39
Model of expanded
IO card
Expanded IO card
0: No
1: Yes
Reserve for 3004GB and
below models
0 × 0327
P2.40
Model of expanded
PG card
Expanded PG card
0: No
1: Yes
Reserve for 3004GB and
below models
0 × 0328
P2.41
Extended PG output
frequency dividing
ratio
Extended PG
frequency
dividing ratio
1~128
Reserve for 3004GB
and below models
1 × 0329
P2.42
Extended PG pulses
per revolution
Extended PG
pulses
1~9999
Reserve for 3004GB
and below models
1000 × 032A
P2.43
Extended PG
direction setting
Extended PG
direction
0: Phase A advances
during positive rotation
1: Phase B advances
during positive rotation
Reserve for 3004GB
and below models
0 × 032B
P2.44
Built-in PG pulses
per revolution
Built-in PG
pulses
1~9999 1000 × 032C
P2.45
Built-in PG
direction setting
Built-in PG
direction
0: Phase A advances
during positive rotation
1: Phase B advances
during positive rotation
0 × 032D
P2.46
Selection of use of
speed measurement
PG
Selection of
use of PG
0: Use built-in PG
1: Use expanded PG
0 × 032E
P2.47
PG disconnection
detection time
(Reserve)
PG
disconnection
detection time
0.0~10.0s 2.0 s × 032F
P2.48
Operation selection
in the event of PG
disconnection
(Reserve)
PG
disconnection
operation
0: Deceleration stopping
1: Free stopping
2: Abnormal stopping
3: Continue to run
1 × 0330
P2.49
Number of PG
reduction teeth 1
Number of PG
reduction teeth
1
1~1000 1 × 0331
P2.50
Number of PG
reduction teeth 2
Number of PG
reduction teeth
2
1~1000 1 × 0332

Table of Contents