Display Meaning
Error E-0001 Communication error between MAIN CPU/DSP, PNL1 UCOM
and PNL2 UCOM
Error E-0002 MAIN CPU/DSP startup error
Error E-0004 Clock generator setting error
Error E-0008 ADC or DAC setting error
Error E-0010 DIR setting error
Error E-0020 DIT setting error
Error E-0040 Authentication Coprocessor (MFI IC) communication error
Error E-0080 Communication error between MAIN CPU/DSP and
USB/ETHER UCOM (Parameter side)
Error E-0100 LAN Reset error
Error E-0200 SUB DSP (SRC) startup error
Error E-0400 Communication error between MAIN CPU/DSP and
USB/ETHER UCOM (Link Cue side)
Display Meaning
The debug LED of USB/ETHER UCOM repeats the
operation of flashing twice and turning off for 1 second.
DDR3L SDRAM check error for USB/ETHER UCOM
The debug LED of USB/ETHER UCOM repeats the
operation of flashing 5 times and turning off for 1 second.
Program road error from FLASH ROM (16Mb) for
USB/ETHER UCOM
The debug LED of USB/ETHER UCOM keeps light on
after product starts up (no flashing).
USB/ETHER UCOM startup error
The debug LED of MAIN CPU/DSP (DSP) keeps light on
after product starts up (no flashing).
MAIN CPU/DSP (DSP) initialization error
The debug LED of MAIN CPU/DSP (DSP) flashes rapidly
when the product starts up (cycle of about 300 milliseconds).
The state that MAIN CPU/DSP (DSP) stopped by some abnormality
The debug LED of MAIN CPU/DSP (ARM) repeats the
operation of flashing twice and turning off for 1 second.
DDR3L SDRAM check error for MAIN CPU/DSP
MIDI START/STOP (WAKE UP) LED on Unit
flashes (cycle of 3 seconds).
Communication error of PNL1 UCOM and MAIN CPU/DSP at startup
MIDI ON LED on Unit flashes (cycle of 250 milliseconds). Communication error of PNL2 UCOM and PNL1 UCOM at startup
The debug LED of SUB DSP keeps light off after product
starts up (no flashing).
SUB DSP startup error
LED
D601
D601
D601
D1501
D1501
D1701
LED of
Unit
LED of
Unit