Disable filters
Switch on to fault
enabled
Pole dead ‘A’
Pole dead ‘B’
Pole dead ‘C’
Zone 1
interrupt
gating
logic
Port A0
PA1
PA2
PA3
PA4
PA5
PA6
PA7
Port B0
PB1
PB2
PB3
PB4
PB5
PB6
PB7
Port C0
PC1
PC2
PC3
PC4
PC5
PC6
PC7
Fault detected by DEF
Contact breaker open
Comparator C–A zone 1
Comparator B–C zone 1
Comparator A–B zone 1
Comparator C–N zone 1
Comparator B–N zone 1
Comparator A–N zone 1
Block Z2T and Z3T
Zero sequence voltage level detector
Comparator C–A zone 3
Comparator B–C zone 3
Comparator A–B zone 3
Comparator C–N zone 3
Comparator B–N zone 3
Comparator A–N zone 3
Channel in service
Carrier received
Comparator C–A zone 2
Comparator B–C zone 2
Comparator A–B zone 2
Comparator C–N zone 2
Comparator B–N zone 2
Comparator A–N zone 2
High set neutral current
level detector
DB
Programmable
peripheral
interface 0
CS
Reset
DB
CS
Reset
Port B0
PB1
PB2
PB3
PB4
PB5
PB6
PB7
Port CD0
PC1
PC2
PC3
PC4
PC5
PC6
PC7
Port A0
PA1
PA2
PA3
PA4
PA5
PA6
PA7
Programmable
peripheral
interface 2
N
C
B
A
Phase
C
B
A
Low set
current level
detectors
Over
voltage level
detectors
Memory input
Memory input
common
‘C’ phase trip
‘B’ phase trip
‘A’ phase trip
Block auto reclose
Any comparator operated
Power swing indication
Self check in progress
Master reset/invert comparators
Fuge fall
Switch on to fault
Aide trip
Zone 3 time delayed trip
Zone 2 time delayed trip
Carrier received annunciation
Any trip
Carrier transmit
Sign wave to square
wave conversion
Push button
and push
button override
Comparator AB zone 6
INT
T1
Port 1
P26
P25
T0
B039
Microcontroller
P20–P23
P27
P24
Reset
DB
4k x 8
aprom
D
AA
8 bit
latch
D
D
CS
Reset
6 bit ‘D’
type flip
flop
D
00
01
02
03
04
05
Reset
pulse
S1
ENSB1
S1
EN socket
S2
ENSB1
S3
ENSB1
S4
ENSB1
CSWX
ENSB1
CSWY
ENSB1
Port A0
PA1
PA2
PA3
PA4
PA5
PA6
PA7
Port B0
PB1
PB2
PB3
PB4
PB5
PB6
PB7
Port C0
PC1
PC2
PC3
PC4
PC5
PC6
PC7
Programmable
peripheral
interface 1
Code switch
enable
monitor
Inoperative
alarm circuits
Inoperative
alarm input
Input
buffer
enable
Phase
A
B
C
Spare
High set
current
level
detectors
Enable
Inoperative
alarm outputs
Power swing
Enable filters
Enable CSW
Enable SB1
Enable SB2
Enable SB3
Enable SB4
Extended zone 1 reach
3 phase trip
Fuse fail indication
Switch on to fault indication
Aided trip indication
Zone 3 time delayed trip indication
Zone 2 time delayed indication
‘C’ phase fault indication
‘B’ phase fault indication
‘A’ phase fault indication
Amplitude hysteresis (trip)
FF
SOTF
AT
Z3
Z2
C
B
A
Indications
‘C’ phase memory output
Memory enabled
Power swing timer run out
Fault location Z3(PH)
Fault location Z2(E)
Fault location Z2(PH)
Fault location Z1(PHLE)
120°
120°
‘A’ phase memory output
‘B’ phase memory output
Enable SK1