EasySet 2 configuration
28
EasySet 2 BAG0217.9
06.22
5.2 Error messages
Message
Type
Description /
trigger condition
Time until
trigger
Effects Remedy
E1
Warning Mode 0 active 0 s Operation not pos-
sible
Set the mode, see
page 28
E6
Warning Left shutter is not
responding;
the actuated setpoint
position cannot be
reached
2 s - Check motor
Eliminate the block-
age, see below.
E7
Warning Right shutter is not
responding
2 s - Check motor
Eliminate the block-
age, see below.
E11
Warning Setpoint value can-
not be maintained
10 s Alternating display:
1 s / E11, then 5 s
ACTUAL value
Adjust forward
speed
E20
Warning The calibration value
is outside of the pre-
scribed limits
0 s Display on the left:
E20
On the right:
calculated value
Repeat calibration
E32
Warning Boundary spreading
setting motor is not
responding
2 s The output of the
boundary spread-
ing system must
be switched off
Check motor
E39
Warning Angle sensor of the
left shutter has failed
0 s - Check the sensor
E40
Warning Angle sensor of the
right shutter has
failed
0 s - Check the sensor
E41
Warning Boundary spreading
sensor failure
0 s - Check the sensor
E50 /
SPEED
Warning With the safety func-
tion, the shutters only
open when a forward
speed signal is avail-
able after 6 seconds.
0 s 5 s continuous
tone
Open the shutter
when the forward
speed is reached.