Cleaning, maintenance and repairs
GreenDrill BAH0054-4 02.13
63
8.2 Cleaning
1. Empty the hopper and dosing unit.
2. Dismantle the sowing shaft to enable intensive cleaning of the dosing unit.
3. Blow out the hopper and dosing unit with compressed air or dry clean it with a paintbrush.
4. Clean only the outside of the hopper with water or a high-pressure cleaner.
No water must enter the hopper or the dosing unit.
The inside of the machine must only be blown out with compressed
air.
DANGER
Dressing dust is toxic and must not be inhaled or come into
contact with the body.
When emptying the machine and removing dressing dust, e.g. with
compressed air, wear a protective suit, face mask, safety goggles and
gloves.
Always observe the following points when using a high pressure
cleaner / steam jet for cleaning:
Do not clean any electrical components.
Always maintain a minimum jet distance of 300 mm between the
high pressure cleaning or steam jet cleaning nozzle and the ma-
chine.
Comply with safety regulations when working with high pressure
cleaners.