120 ARX 23-2 T4i, ARX 26-2 T4i
h
1/4
2/4
1
3/4
9V
11V
15V
13V
3.6 Lubrication and maintenance operations
Every 20 hours of operation (daily)
3.6.1 Fuel check
Check the fuel level on the dashboard and rell if necessary.
Clean the tank cap and the ller neck.
Unlock the lock and remove the cap.
Rell the tank up to the bottom line of the ller neck.
Note
The fuel tank volume is 35l (9.3galUS).
Fill up the same fuel type; see Chap. 3.2.2.
Check the fuel tank and the fuel circuit for leaks.
Do not smoke and do not use open ame while working.
Do not rell the fuel when the engine is running.
Stop the fuel soaking into the ground.