164 ARX 23-2 T4i, ARX 26-2 T4i
3.6 Lubrication and maintenance operations
3.6.49 Fuel system venting
Vent the fuel system before the rst start in the following cases:
• When fuel lters have not been lled with fuel – when re-
placing the lters
• when replacing the fuel pump
• when repairing the fuel system
• during long term shutdown of the machine
• when the tank is empty.
3.6.48 Draining water from the sprinkling
circuit before the winter season
Water must be drained from the sprinkling circuit before the
winter season because the individual parts may get damaged
due to frost.
Procedure for draining water from the sprinkling circuit
Release the quick coupler of the sprinkling hose.
Push the ring against the screw joint.
Remove the hose from the coupler.
The water will ow out automatically.
Turn on the sprinkling and let the pump run briey. The remain-
ing water will ow out.
Removal of the sprinkling lter
Remove and clean the vessel with the sprinkling lter. Keep the
vessel with the lter in asafe place.