EasyManua.ls Logo

Ammann ARX 23-2 - Draining Water from the Sprinkling Circuit before the Winter Season; Fuel System Venting

Ammann ARX 23-2
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
164 ARX 23-2 T4i, ARX 26-2 T4i
593057
3.6 Lubrication and maintenance operations
3.6.49 Fuel system venting
Vent the fuel system before the rst start in the following cases:
When fuel lters have not been lled with fuel – when re-
placing the lters
when replacing the fuel pump
when repairing the fuel system
during long term shutdown of the machine
when the tank is empty.
3.6.48 Draining water from the sprinkling
circuit before the winter season
Water must be drained from the sprinkling circuit before the
winter season because the individual parts may get damaged
due to frost.
Procedure for draining water from the sprinkling circuit
Release the quick coupler of the sprinkling hose.
Push the ring against the screw joint.
Remove the hose from the coupler.
The water will ow out automatically.
Turn on the sprinkling and let the pump run briey. The remain-
ing water will ow out.
Removal of the sprinkling lter
Remove and clean the vessel with the sprinkling lter. Keep the
vessel with the lter in asafe place.

Table of Contents

Related product manuals