37ARX 23-2 T4i, ARX 26-2 T4i
OPERATING MANUAL
2.3.3 Machine depreservation
• Check all parts of the machine for damage during storage
and for missing parts.
If the machine has been preserved, remove the preserva-
tive agents as follows:
Wash o the preservative agents using a high-pressure
stream of hot water with common degreasers:
- Wash the machine while observing environmental
principles.
- Caution! Do not use a high-pressure stream to wash
the edge cutter and the highlighted parts of the ma-
chine as shown in Fig. 588589A, as this could serious-
ly damage the machine.
- Prevent water from entering the air lter, electrical
and electronic parts of the machine.
- Do not use a high-pressure stream near the control
unit!
- Use a high-pressure stream at a maximum angle of 90
degrees downwards.
Remove the preservation and wash the machine in pla-
ces with intercepting sumps to catch the water and de-
-preservation agents.
Remove the preservation according to the manufacturer's man-
ual.
Before putting the machine into operation, check the op-
erating uids.