MEASUREMENTS & CONDITIONS FOR ALCOHOL TESTING
Use a clean sampling cup or straw for each test. Sampling cups should be replaced after
each positive BAC test result or when it is dirty.
Do not allow samples containing smoke, tobacco or other chemical products to enter the unit,
as damage to the fuel cell can occur. Cigarette smoke may also increase the blood alcohol
concentration value displayed. Allow one minute after smoking before testing.
There must be an interval of at least 15 minutes after alcohol consumption as alcohol residue
in the mouth may give a false reading. Such residue may also be left by aromatic drinks,
mouthwash, medicines and drops, as well as by belching and vomiting. Rinsing your mouth
with water or non-alcoholic drinks does not substitute for an interval.
A person's blood alcohol concentration (BAC) can continue to rise for up to 2 hours after
drinking alcohol. If a result is close to the designated BAC, it is recommended to wait and
retest after 20 minutes.
It can take 10 hours or more for a person's BAC to return to zero after a high BAC has been
reached. A further test should be carried out later in the day or the following morning.
LIABILITY FOR PROPER FUNCTION OR DAMAGE
The liability for proper functioning of the instrument is irrevocably transferred to the owner or operator
in the event the instrument is serviced or repaired by personnel not employed or authorised by
Andatech. In such an event, the warranty will be void.
30
WARRANTY
The manufacturer warrants for 1 year from the
date of purchase, the product to be free from
defects in workmanship or material (excluding
recalibration) under normal use. The
manufacturer’s obligation under this warranty is
limited to replacing, adjusting or repairing the
unit if returned along with proof of purchase.
This warranty is void if the unit has been
tampered with, damaged or abused in any way.
Visit my.andatech.com.au to register your
warranty online and receive calibration
reminders.
BREATHALYSER
CALIBRATION & SERVICE
Andatech recommends the Andatech
®
Soberlive
FRX to be calibrated every 6 months. The
Soberlive FRX cannot be used to take a test
once it has passed its calibration due date.
To register your product warranty, receive
calibration reminders and book in a calibration,
please go to my.andatech.com.au or contact:
Andatech
Hotline: 1300 800 200
Website: www.andatech.com.au