Use and installation manual
Make the connection in compliance with the relevant legal requirements, using
appropriate and recommended materials.
Water supply connection
Connect the mains line to the appliance's connection
pipe, fitting a shut-off tap (B) to allow the water supply
to be cut off when necessary.
The tap (B), not supplied with the appliance, must
be installed in an easily accessible position and
its status (on or off) must be obvious at a glance.
The appliance must be supplied with drinking wa-
ter having the characteristics shown in the table.
If these characteristics are not complied with the
appliance might suffer damage; a water treat-
ment device should therefore be installed.
(*) The value refers to the amount of water needed for steam production inside the cooking chamber.
For the United Kingdom only, also see instructions provided in the enclosure
(See "Water connection (WRAS)").
To carry out this operation, proceed as follows.
1–Connect the mains water pipe (A) to the appliance's connection pipe (C).
2–Connect the vent pipe (D) to the appliance connection pipe (C) and fix it to the sup-
port (E).
WATER CONNECTION
Description Value
Pressure 200÷400 kPa (2÷ 4 bar) (*)
Water flow rate (l/h)
17,5 l/h (FX 82) (*)
17,5 l/h (FX 122) (*)
pH 7÷7.5
Conductivity < 200µS/cm
Hardness 9÷13°f (5÷7°d, 6.3÷8.8°e, 90÷125 ppm)
Salt and metallic ion content
Chlorine
Chlorides
Sulphates
Iron
Copper
Manganese
<0,1 mg/l
< 30 mg/l
< 40 mg/l
< 0,1 mg/l
< 0.05 mg/l
< 0,05 mg/l
WATER DRAIN CONNECTION