CNC Motion Setup/Testing Utility
P/N 70000635C
All rights reserved. Subject to change without notice.
November 2009
31
s display two possible results:
ted a retract lag of 51
The following graphic
• Refer to Figure 18. Axes optimally tuned repor
microns.
0 1 2 3 4 5 6 7 8 9
-30
-20
60
-10
0
10
20
30
40
50
microns
seconds
mally Tuned Screen Figure 18, Axes Opti
• Refer to Figure 19. Z-axis without being optimally tuned (default
gains). Reported retract lag was 79 microns and threading lag of 12
microns.
0 1 2 3 4 5 6 7 8 9
-40
-20
0
20
40
60
80
seconds
Figure 19,
microns
Z-axis Not Optimally Tuned Screen