Questions and Answers

  • L
    Lori MoralesSep 6, 2025
    What to do if Applied Biosystems Laboratory Equipment has no beep?
    • T
      Thomas ClaySep 6, 2025
      For the Applied Biosystems Laboratory Equipment, check Run-Time Beep configuration.
  • D
    Daisy ThomasAug 25, 2025
    Why does my Applied Biosystems GeneAmp PCR System 9700 printer fail?
    • J
      Jose BaldwinAug 25, 2025
      If your Applied Biosystems Laboratory Equipment printer fails, verify the printer settings (baud rate = 9600, no parity, one stop bit, eight data bits) and ensure you are using the correct Applied Biosystems printer cable.
  • Y
    Yvette JamesAug 25, 2025
    Why is my Applied Biosystems GeneAmp PCR System 9700 making too much noise?
    • R
      Ryan PearsonAug 26, 2025
      If the Applied Biosystems Laboratory Equipment is making too much noise, check for any obstructions in the side vents.
  • T
    tiffany20Sep 15, 2025
    What to do if Applied Biosystems Control Unit displays 'Remove infinity hold first'?
    • K
      Keith WelchSep 15, 2025
      To resolve this issue on Applied Biosystems Control Unit, add segments prior to the post-PCR infinity hold.
  • A
    Andrew ThompsonSep 23, 2025
    What to do if Applied Biosystems Control Unit shows 'Enter a name or CANCEL'?
    • C
      Courtney WagnerSep 23, 2025
      To fix this, enter the user name to which the desired method is assigned on Applied Biosystems Control Unit.
  • X
    xstephensSep 12, 2025
    What to do if Applied Biosystems Control Unit has no screen display and no response when turned on?
    • K
      Kathleen McdanielSep 12, 2025
      To resolve this issue with Applied Biosystems Control Unit, ensure the power switch is ON, the power cord is connected, and check the fuses.
  • D
    Donald Stevens Jr.Sep 2, 2025
    What to do if Applied Biosystems GeneAmp PCR System 9700 displays 'Method requires at least one segment'?
    • A
      Angela LittleSep 2, 2025
      To resolve the 'Method requires at least one segment' error on your Applied Biosystems Laboratory Equipment, review and correct the method to include the temperature parameter(s).
  • C
    Christopher GloverSep 2, 2025
    How to fix 'No seconds in time field' error on Applied Biosystems GeneAmp PCR System 9700?
    • W
      William HannaSep 3, 2025
      To resolve the 'No seconds in time field' error on your Applied Biosystems Laboratory Equipment, include seconds when entering the time.
  • C
    Carolyn JenkinsSep 22, 2025
    What to do if Applied Biosystems Control Unit displays warning 'Block version unknown'?
    • C
      ccarrollSep 22, 2025
      To resolve this issue with Applied Biosystems Control Unit, upgrade firmware.
  • A
    Amy WareAug 28, 2025
    Why Applied Biosystems GeneAmp PCR System 9700 cooling fan does not make whirring sound?
    • L
      laurielamAug 29, 2025
      To fix the issue where the Applied Biosystems Laboratory Equipment instrument cooling fan does not make a whirring sound, verify that the power switch is on, the power cord is connected, and check the fuses.

Summary

Introduction and Safety

Product Overview

Instrument Setup

Instrument Configuration and Operation

Procedures for powering on, configuring settings, and customizing instrument parameters.

Running PCR Samples

Selecting a Method

Guide to choosing, viewing, searching, and sorting PCR methods.

Running a Method

Steps to start, monitor, and pause a PCR run using the instrument.

Stopping and Completing Runs

Procedures for stopping, aborting, reviewing history, and handling run completion.

Creating and Editing Methods

Creating and Modifying PCR Methods

Guide to creating new methods and modifying cycling parameters like holds, cycles, and pauses.

Method Storage, Printing, and Deletion

Steps for naming, storing, printing, editing, and deleting created methods.

Routine Maintenance

Changing External Fuses

Step-by-step instructions for safely replacing the instrument's external fuses.

Troubleshooting

Display Screen Error Messages

A table of error messages, their causes, and recommended actions.

Troubleshooting Information Table

A table listing common problems, their causes, and suggested remedies.

Instrument Specifications

Applied Biosystems GeneAmp PCR System 9700 Specifications

General IconGeneral
Temperature Range4°C to 99.9°C
Temperature Accuracy±0.25°C
Temperature Uniformity±0.5°C
Block Format96-well
Temperature Uniformity at 60°C±0.5°C
DisplayLCD
Power Requirements100-240V, 50/60Hz
Sample Capacity96 samples
Sample Volume Range10-100 µL