EasyManua.ls Logo

Applied Biosystems QuantStudio 6 Flex User Manual

Applied Biosystems QuantStudio 6 Flex
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
For Research Use Only. Not for use in diagnostic procedures.
QuantStudio
6 and 7 Flex Real-Time PCR
Systems
USER GUIDE
Maintenance and Administration
for use with QuantStudio
RealTime PCR Software v1.6
Publication Number MAN0018828
Revision A.0

Table of Contents

Questions and Answers:

Applied Biosystems QuantStudio 6 Flex Specifications

General IconGeneral
TypeReal-Time PCR System
Number of Channels6
Excitation SourceLED
MultiplexingYes
Temperature Accuracy±0.25°C
Temperature Uniformity±0.5 °C
SoftwareQuantStudio Design and Analysis Software
ConnectivityUSB, Ethernet
Format96-well, 384-well
Detection MethodFluorescence
Optical SystemFilter-based
Temperature Range4 to 100°C
Power Requirements100–240 VAC, 50/60 Hz

Summary

About this guide

Purpose

Explains the scope and intent of the user guide.

Audience

Identifies the intended readers of the guide.

Assumptions

Lists prerequisites and prior knowledge assumed for users.

User attention words

Explains specific words used to convey levels of observation or action.

CHAPTER 1 Getting started

Differences between the QuantStudio 6 and 7 Flex Real-Time PCR Systems

Details the differences between the QuantStudio 6 and 7 Flex PCR Systems.

Data collection

Explains how the instrument collects raw fluorescence data during PCR.

Instrument filters and supported dyes

Describes the instrument's optical filters and the dyes they support.

Instrument hardware

Details the physical components of the instrument.

Instrument software

Describes the software applications used for instrument operation.

Instrument consumables

Lists the specialized consumables supported by the instrument.

CHAPTER 2 Calibrate the instrument

Calibration overview

Provides an overview of instrument calibration procedures and schedules.

Calibration workflow

Outlines the sequence for performing instrument calibrations.

Define the mail server settings

Details how to configure SMTP server settings for email notifications.

Modify the notification settings for a monitored instrument

Explains how to adjust notification settings for specific instrument calibrations.

Guidelines for preparing calibration plates and array cards

Provides essential guidelines for preparing calibration consumables correctly.

Preparing array cards for instrument calibration

Details the process for preparing array cards for calibration.

ROI calibration

Details the process of calibrating the Region of Interest.

Background calibration

Details the process of performing background calibration.

Uniformity calibration

Details the process of performing uniformity calibration.

Dye calibration

Details the process of performing dye calibration.

Normalization calibration (TaqMan Array Card only)

Details normalization calibration specific to TaqMan Array Cards.

Verify the instrument performance

Describes how to perform tests to verify instrument performance.

Troubleshooting

Provides solutions for common calibration and verification issues.

APPENDIX A Manual instrument operation

Overview of instrument touchscreen functions

Summarizes the functions available via the instrument's touchscreen interface.

Operate the instrument from the touchscreen

Details how to perform basic operations using the touchscreen.

Run an experiment

Explains the steps to start and run an experiment on the instrument.

Transfer experiments, templates, and results data

Describes how to transfer data to and from the instrument using USB drives.

Maintain the instrument from the touchscreen

Covers maintenance tasks accessible via the touchscreen.

Perform an instrument self test

Describes how to run a comprehensive self-test for instrument diagnostics.

Administrate the instrument from the touchscreen

Covers administrative functions available on the touchscreen.

Define the instrument settings

Covers configuring basic instrument settings like name and icon.

Define the network settings

Guides the configuration of network parameters for instrument connectivity.

Enable or disable instrument security

Covers enabling/disabling secure mode and administrator password management.

APPENDIX B Maintenance

Decontaminate the sample block

Provides steps to clean and decontaminate the sample block from contaminants.

Replace the halogen lamp

Details the procedure for replacing the instrument's halogen lamp.

Replace the instrument fuses

Guides the process of replacing instrument fuses if they fail.

Install the QuantStudio Real-Time PCR Software

Explains how to install the QuantStudio software.

Software licenses

Covers licensing for optional software modules like HRM.

Update the QuantStudio Real-Time PCR Software

Explains how to download and install software updates.

Change the sample block

Details how to replace the instrument's sample block.

Change the heated cover

Guides the replacement process for the instrument's heated cover.

Change the plate adapter

Explains how to change the plate adapter for different consumable formats.

APPENDIX C Networking

Networking overview

Introduces network connectivity for QuantStudio systems.

Network setup workflow

Outlines the steps for connecting the instrument to a local area network.

Connect the QuantStudio 6 or 7 Flex System to the network

Details connecting the instrument to the network via Ethernet.

Connect the computer to the network

Guides connecting the control computer to the network.

Monitor the QuantStudio 6 or 7 Flex Real-Time PCR System

Describes how to remotely monitor the instrument status via software.

APPENDIX D Power on or off, store, and move

Place the QuantStudio 6 or 7 Flex Real-Time PCR System on standby

Explains how to put the instrument into standby mode.

Power on the QuantStudio 6 or 7 Flex Real-Time PCR System

Details the procedure to power on the instrument and associated computer.

Store the QuantStudio 6 or 7 Flex System

Provides guidance on storing the instrument for extended periods.

Move the QuantStudio 6 or 7 Flex System

Provides safety and procedural guidelines for safely moving the instrument.

Reinstall the QuantStudio 6 or 7 Flex System

Guides the process of reinstalling the instrument after moving.

APPENDIX E Security, audit, and electronic signature

Administrator overview

Introduces the Security, Audit, and Electronic Signature module features.

Configure the security system

Details how to enable/disable security and set user policies.

Set account setup and security policies

Covers configuring user account limits and password policies.

User account management

Guides the creation, editing, and management of user accounts.

Create or edit a user role

Details how to create or modify user roles and their permissions.

Audit trail management

Covers management of the audit trail feature.

Audit report generation

Details how to generate and manage audit reports.

Manage electronic signature

Covers management of the electronic signature feature.

Select the actions that require signature

Defines which actions require electronic signatures and how many.

Export and import user, security, audit, and e-signature settings

Covers exporting and importing security configurations for multiple systems.

APPENDIX F Calibration consumable preparation

Create a background plate or array card

Guides the preparation of consumables for background calibration.

Create a custom dye plate for calibration

Details the process for preparing a custom dye plate for calibration.

APPENDIX G Parts and materials

How to order

Explains how to order parts and accessories directly from the website or software.

Kits, consumables, and accessories

Lists available kits, consumables, and accessories for the systems.

APPENDIX H Instrument specification and layout

QuantStudio 6 and 7 Flex Systems specifications

Provides physical dimensions and weight specifications for the instruments.

Required clearances

Specifies the necessary space around the instrument for proper operation.

Electrical requirements

Outlines the electrical power and connection requirements for the system.

Environmental requirements

Lists environmental conditions (altitude, temp, humidity) for instrument operation.

Network requirements

Details network connectivity requirements and hardware.

QuantStudio 6 and 7 Flex Systems layout and connections

APPENDIX I Safety

Symbols on this instrument

Explains safety symbols and their meanings found on the instrument.

Standard safety symbols

Lists and describes common safety symbols with their associated warnings.

Additional safety symbols

Lists additional safety symbols related to laser, moving parts, and hazards.

Location of safety labels

Shows the physical placement of safety labels on the instrument.

Control and connection symbols

Explains symbols for power and connectivity ports on the instrument.

Instrument safety

Provides general safety precautions for instrument operation and maintenance.

Physical injury

Warns about hazards related to moving parts and lifting the instrument.

Electrical safety

Covers crucial safety information regarding electrical supply and handling.

Cleaning and decontamination

Details safe methods for cleaning and decontaminating the instrument.

Laser safety—barcode scanner

Explains laser safety precautions for the barcode scanner.

Workstation safety

Offers recommendations for ergonomic workstation setup to prevent injury.

Safety and electromagnetic compatibility (EMC) standards

Lists standards the instrument complies with for safety and EMC.

Chemical safety

Provides general safety guidelines for handling chemicals in the laboratory.

Biological hazard safety

Addresses safety precautions when working with potential biohazards.

APPENDIX J Documentation and support

Related documentation

Lists other relevant documents for the QuantStudio systems.

Limited product warranty

Outlines the terms and conditions of the product warranty.

Glossary

Related product manuals