1508685 Rev D CHP Max Element Management Modules CHP-CMM, CMM-1, SMM, and SMM-1 6-37
Figure 6.28
FTP Transfer
Complete Message
FTP Failures
1. Bad file name:
The SMM version 1.1 software requires that the file names of the Images transferred be
SMMImage1.S19 and SMMImage2.S19. It will not allow any other file name to be
downloaded. The error message shown by the FTP session will report:
500 Requested download not completed, bad file
It will not prevent a user from copying a bad file to this file name and downloading it.
The FTP session only checks the file name.
2. Bad command:
The SMM version 1.1 software will only understand a “put” command so that software
can be downloaded to the module. If another command such as “get” is entered the
SMM will report:
200 PORT command successful
540 User banned or 502 Command not implemented
3. Incorrect user name or password
The SMM FTP session will only connect using the user name CCOR and the correct
password. If you attempt to log in with a different name or password the SMM will
report:
532 Login incorrect
Connection closed by remote host

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arris CHP Max5000 and is the answer not in the manual?

Arris CHP Max5000 Specifications

General IconGeneral
BrandArris
ModelCHP Max5000
CategoryMulti-service Platforms
LanguageEnglish

Related product manuals