10. Specifications and Calibration
The following subsections provide specifications and calibration information.
10.1 Meazura MEZ1500 Specifications
Operating System: Palm/Garnet OS5.4
Memory: 64MB SDRAM, 128MB Flash
Display: 240x320 Color, backlit LED
Communications: USB (cable provided)
Serial (921.6Kbs)
Battery: 7.4V Li-Ion 1700mAh
Sealing: IP67 – submersible to 1 meter (30 min)
Current Consumption: 60-120mA (depending on screen brightness) unit ON (excluding
module) 120mA typical (maximum brightness).
5 mA Sleep mode
Contact support@aceeca.com for more information on the base Aceeca Meazura unit or
for additional accessories.
10.2 Handheld Programmer Module Specifications:
406 receiver range: -60 dBm to +36 dBm (5W)
Power source: Meazura internal battery
Decoding: Per COSPAS/SARSAT C/S T.001, Issue 3 Rev. 5
Current Consumption: 10 mA unit ON
<100 nA Sleep mode
10.3 Calibration
The Handheld Programmer is factory calibrated and does not require periodic re-
calibration.