Plus4YouTS
User Manual
58 of 216
Periodic maintenance table
Component Type of operation
Weekly
Monthly
Quarterly
PRESSURE TRANSDUCER
Keep the heating unit pressure indicated on the display between 0.08 and 0.14
MPa (0.8 and 1.4 bar).
X
PRESSURE TRANSDUCER
Periodically check the water pressure indicated on the display when coffee is being
dispensed: check the pressure indicated on the gauge, which must be in the range
of 0.8 to 0.9 MPa (8 and 9 bar).
X
FILTERS AND FILTER HOLDERS
Check the condition of the lters. Check for any damage on the edge of the lters
and check whether any coffee grounds settle in the coffee cup, and replace the
lters and/or lter holders, as required.
X
GRINDER-DISPENSER
Check the ground coffee dose (between 6 and 7 grams per time) and check the
degree of grinding. Grinders must always have sharp cutting edges. Too much pow-
der in the grounds is an indication that the coffee is deteriorating. We recommend
calling out the Technician to replace the at burrs after every 400/500 kg of coffee,
or after every 800/900 kg for conical burrs.
X
WATER FILTER
WATER SOFTENER
Replace the water lter cartridge or regenerate the water softener as often as speci-
ed by the manufacturer.
X
HEATING UNITS
We recommend calling out the Technician at least once every three months to
replace the water in the heating unit.
X
- Alarm Description -
Alarm signal
Malfunctions and solutions
Problem Cause Action
NO MACHINE
POWER
The machine is switched off. Turn on the machine.
NO WATER IN THE
HEATING UNIT
The water mains valve is shut off. Open the water mains valve.
TOO MUCH WATER IN
THE HEATING UNIT
Electrical system or hydraulic system fault. Turn off the machine and call out the Technician.
STEAM NOZZLES
DO NOT RELEASE STEAM
• The nozzle sprayer is clogged.
• The machine is switched off.
• Clean the steam nozzle sprayer.
• Turn on the machine.
STEAM NOZZLES RELEASE
WATER OR STEAM
MIXED WITH WATER
Electrical system or hydraulic system fault. Turn off the machine and call out the Technician.
NO BEVERAGES ARE
BEING DISPENSED
• The water mains valve is shut off.
• The coffee has been ground too nely.
• Open the water mains valve.
• Adjust the coffee grinding.