Commissioning
Parameter adaption to the heating system
Parameter
Name Description
Factory
settings
Fix Flow T
Basic thermoregulation
Room T Only
Outdoor T Only
Room + Outdoor T
4 Zone1 Parameters
4.1 Summer / Winter Changeover
4.1.0 S/W function activation 0 = OFF, 1 = ON 0 ** ** ** ** **
4.1.1 S/W temperature treshold 10 - 30°C 20°C ** ** ** ** **
4.2 Zone 1 Settings
4.2.0 Zone temperature range
0 = Low Temp (From 20°C to 45°C)
1 = High Temp (From 35°C to 85°C)
1 *****
4.2.1 Thermoregulation
0 = Fix Flow T
1 = Basic thermoregulation
2 = Room T Only
3 = Outdoor T Only
4 = Room + Outdoor T
1 01234
4.2.2 Slope
From 1.0 - 3.5 HT
From 0.2 - 1.0 LT
1.3HT
0.6LT
*****
4.2.3 2ႇVHW
HT: From -14°C to +14°C
LT: From -7°C to +7°C
0
0
*****
4.2.5 Max T
HT: From 20°C to 82°C
LT: From 20°C to 45°C
82°C
45°C
*****
4.2.6 Min T
HT: From 20°C to 82°C
LT: From 20°C to 45°C
40°C
25°C
*****
4.2.8 Quick night setback 0 = OFF / 1 = ON 0
*****
4.2.9 Heat reguest mode
0 = Standard
1 = RT Time Programs Exclusion
2 = Forcing Heat Demand
0 **********
Value = mandatory setting
* adapt to the design characteristics of the heating system
** adapt to the comfort needs of the customer