Parameters
Downloading of the parameters
All the parameters values below have a tratment by the ATEQ device as Long format with fixed comma
(10
-3
). A Long is a two words set.
Identifier
Meaning
Value
Dec
Hexa
01
0001
“FILL TIME”
Fill time
0 > 650 seconds
02
0002
“STAB TIME”:
Stabilization time
0 > 650 seconds
03
0003
“TEST TIME”
Test time
0 > 650 seconds
06
0006
“PRE FILL”
Pre fill time
0 > 650 seconds
07
0007
“PRE DUMP”
Pre dump time
0 > 650 seconds
09
0009
“DUMP TIME”
Dump time
0 > 650 seconds
10
000A
“COUPL. A”:
Coupling time 1
0 > 650 seconds
11
000B
“COUPL. B”:
Coupling time 2
0 > 650 seconds
17
0011
“Min Vol.”
Minimum volume reject level (volume test type
measure)
0 > 9999
18
0012
“Max. Vol.”
Maximum volume reject level (volume test type
measure).
0 > 9999
20
0014
“VOLUME”
Part volume.
0 > 9999
21
0015
“TYPE”:
Test type
Invalid
Leak
Blockage
Desensitized
Operator
Burst test
Volume test
0000
1000
2000
3000
4000
5000
6000
29
001D
“Inter-Cycle”:
Time between 2 chained cycles
0 > 650 seconds
48
0030
“DURATION”
Maintain time of the result during stamp
0 > 650 seconds
50
0032
“Min FILL”
Minimum pressure value
- 9999 > 9999
51
0033
“Max FILL
Maximum pressure value
- 9999 > 9999