The following control modes can be selected:
• Local control: The compressor will react to commands entered by the buttons on the control panel.
Compressor start/stop commands via Clock function are active, if programmed.
• Remote control: The compressor will react to commands from external switches. Emergency stop remains
active. Compressor start/stop commands via Clock function are still possible.
Options:
• Remote starting and stopping (switch S1')
• Remote loading/unloading (external pressure switch S4')
• Remote pressure sensing (switch S'):
• LAN control: The compressor is controlled via a local network. Consult Atlas Copco.
See section Electrical system to locate the connectors.
5.4 Pictographs
Pictographs GA 15 up to GA 22
Reference Designation
1 Warning: before connecting compressor electrically, consult Instruction book for motor
rotation direction
2 Torques for steel (Fe) or brass (CuZn) bolts
3 Warning: suction
4 Lightly oil gasket of oil filter, screw filter on and tighten by hand (approx. half a turn)
5 Consult the instruction book before carrying out maintenance
6 Warning: voltage
7 Warning: hot parts
8 Lock all doors of the bodywork before starting.
•
If the sheet is pulled downwards: stop the compressor and switch off the voltage.
•
Reverse two incoming lines. Repeat the previous step.
•
If the sheet is blown away the motor rotation is correct.
9 Manual condensate drain
10 Automatic condensate drain
11 Warning: switch off the voltage and depressurise compressor before repairing