EasyManua.ls Logo

Atlas Copco GA 15

Atlas Copco GA 15
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
This screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1191>. In the example shown, the
compressor has run 1191 hours since the previous service.
Resetting the service timer
After servicing, see section Service warning, the timer has to be reset:
Scroll to register screen <d.6> and press Enter button (13).
The reading (e.g. 4000) will appear.
Press Enter button (13) and - if a password is set - enter the password.
The icon will flash (indicating that resetting is possible).
Press Enter button (13) to reset the timer to <0.000> or press the Escape button (14) to cancel the operation.
3.16 Selection between local, remote or LAN control
Starting from the Main screen:
Press Scroll button (12) until <P.01> is shown and then press Enter button (13). The actually used control
mode is shown: <LOC> for local control, <rE> for remote control or <LAn> for LAN control.
Press Enter button (13) and if necessary enter the password. The actually used control mode is blinking.
Use Scroll button (12) to change the control mode.
Press Enter button (13) to program the new starting mode or press Escape button (14) to cancel.
3.17 Calling up/modifying CAN address control
Calling up
Starting from the main screen,
Press the Scroll button (12) until <P.02> is shown and then press Enter button (13).
Instruction book
2920 7083 31 43

Table of Contents

Related product manuals