Type V Hz Approval I
tot
P
(1)
I
tot
FF
(1)
Recommended wire
section (2)
Recommended wire
section (3)
Main
fuses
(A) (4)
GA 22 575 60 UL/cUL 37 42 4 x AWG6 4 x AWG4 50
Remarks :
(1): current in the supply lines at maximum load
(2): suggested wire section under standard conditions (Pack)
(3): suggested wire section under worst case conditions (Full-Feature)
(4): Maximum fuse value - value between ( ) valid in case of 6 fuses for parallel supply cables
Fuse specifications IEC: gL/gG
Fuse specifications UL/cUL: HRC Form II - UL: Class 5
10.3 Settings for motor overload relay
Overload relay settings
GA 15 GA 18 GA 22
Frequency (Hz) Voltage (V) Overload relay F21 (A) Overload relay F21 (A) Overload relay F21 (A)
IEC Star-delta
50 230 39 47 58
50 400 23 27 34
50 500 18 22 27
60 380 23 28 35
UL/cUL Star-delta
60 200 43 53 65
60 230 37 46 60
60 460 19 23 30
60 575 15 18 23
10.4 Dryer switches
General
The regulating and safety devices are factory-adjusted to give optimum performance of the dryer.
Do not alter the setting of any of the devices.