6.4 During operation
Warnings
The operator must apply all relevant Safety precautions. Also consult section Problem
solving.
Removing the front panel (service panel) during operation will lead to an automatic shutdown
of the unit after a certain time depending of the compressor version.
When the motors are stopped and LED (8) (automatic operation) is alight, the motors may
start automatically.
Checking the oil level
When the automatic operation LED (8) is lit, the regulator is automatically controlling the
compressor, i.e. loading, unloading, stopping of the motors and restarting!
Control panel Elektronikon®
Control panel Elektronikon® Graphic
Regularly check the oil level. To do this, press the stop button (9). Three minutes after stopping, sight-glass
(Gl) should be between 1/4 and 3/4 full.
If the oil level is too low, press the emergency stop button (10), close the air outlet valve and open (if provided)
the manual condensate drains. See section Introduction and section Condensate system for location of the
outlet valve and the water drain. Next, depressurise the oil system by unscrewing oil filler plug (FC) one turn
Instruction book
126 2920 7083 31