6.6 Stopping
Elektronikon regulator
Control panel Elektronikon®
Control panel Elektronikon® Graphic
Procedure
Step Action
- Press stop button (9). Automatic operation LED (8) goes out and the compressor stops
after 30 seconds of unloaded operation.
- To stop the compressor in the event of an emergency, press emergency stop button
(10). Alarm LED flashes (7).
On compressors with an Elektronikon® controller: remedy the problem cause, unlock the
button by pulling it out and press the Escape button (5) to reset.
On compressors with an Elektronikon® Graphic controller:
•
Remedy the problem cause and unlock the button by pulling it out.
•
Navigate to the Stop icon on the display by means of the navigation keys (3/4) and
press the Select key.
Press reset.
Do not use emergency stop button (10) for normal stopping!
- Close air outlet valve (AV), see section Introduction.
- Open the manual drain (Dm).
Switch off the voltage.