6.5 Checking the display
Procedure
Control panel of the Elektronikon® controller
Control panel of the Elektronikon® Graphic controller
Compressors with Elektronikon® controller:
Check the display (2) regularly for readings and messages. The display normally shows the compressor outlet
pressure, while the status of the compressor is indicated by pictographs. Remedy the trouble if alarm LED
(7) is lit or flashes, see section Shutdown warning , Shutdown and Problem solving. The display (2) will show
a service message if a service plan interval has been exceeded or if a service level for a monitored component
has been exceeded. Carry out the service actions of the indicated plans or replace the component and reset
the relevant timer, see section Service warning.
Compressors with Elektronikon® Graphic controller:
Check the display (2) regularly for readings and messages. The display normally shows the compressor outlet
pressure,while the status of the compressor is indicated by means of a number of icons. Remedy the trouble
if alarm LED (7) is lit or flashes, see section Icons used. The display (2) will show a service message if a
service plan interval has been exceeded or if a service level for a monitored component has been exceeded.
Carry out the service actions of the indicated plans or replace the component and reset the relevant timer, see
section Service menu.
Instruction book
128 2920 7083 31