EasyManua.ls Logo

Atlas Copco GA 15

Atlas Copco GA 15
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
References Description
1 Compressed air flow towards the condensate trap (Pack units).
Compressed air flow to the air dryer (compressors with integrated dryer)
A Intake air
B Air/oil mixture
C Oil
D Wet compressed air
Description
In oil tank (OT) most of the oil is removed from the air/oil mixture by centrifugal action. The rest is removed
by oil separator (OS). The oil collects in the lower part of oil tank (OT).
Air pressure forces the oil from oil tank (OT) through oil cooler (Co) and filter (OF) to compressor element
(E).
The oil system is provided with a thermostatic bypass valve (BV). When the oil temperature is below its set
point, bypass valve (BV) shuts off the supply to oil cooler (Co) and the oil cooler is bypassed.
Thermostatic bypass valve (BV) starts opening the supply from cooler (Co) when the oil temperature has
increased to the set point. At approx. 15 ˚C (27 ˚F) above the set point, all the oil flows through the oil cooler.