Checking the adapter plate and
the breaker box for cracks
and/or wear
♦
Check the adapter plate and the breaker box for
cracks every week.
♦
Have rework activities or repairs carried out in time
to avoid major damage.
♦
The wear rails (A) in the lower section of the
breaker box can be replaced as required. Please
consult the Atlas Copco Customer Center/dealer
in your area.
If the wear rails have worn severely, this may cause
damage to the basic body of the breaker box.
Checking the adapter plate
bolts for wear
♦
Carry out this visual check whenever the hydraulic
attachment has been removed from the carrier.
♦
Check the adapter plate bolts for excessive wear
such as cracks, pitting or severe erosion.
♦
Rework or replace worn bolts.
© 2012 Atlas Copco Construction Tools GmbH | No. 3390 5005 01 | 2012-05-03
Original instructions
54