I/O Description
DI COMMON 0-5 Connect to +24V IO
or external +24V
(not at the same time)
DI COMMON 6-11 Connect to +24V IO
or external +24V
(not at the same time)
GND Ground
USB device
Type B receptacle.
This connection is used when the controller is connected to one computer.
USB host
Type A receptacle.
Supports:
• Full speed, 12 Mbps
• Low speed, 1.5 Mbps
If you connect an accessory in this connection the controller will be the host
and control the accessory.
Connect a USB hub
It is possible to connect an USB hub with up to 4 ports to the USB host port.
The total max current of the connected devices is 900 mA. If more current is
needed, connect an external power supply.
The USB hub can have two scanners connected at the same time if their total
max current is less than 900mA.
Only scan with one scanner at the time when two scanners are connected.
Do not connect more than one USB flash drive, since only one USB flash drive
can be detected by the MTF 6000.
Ethernet
RJ 45 connector.
The ethernet connection is used to connect the controller to the factory network.
VP - Vacuum pump output
5-pole socket connector for the connection with Atlas Copco Vacuum pump.
Use a 5-pole pin plug from the Binder 719 Series.
Pin Signal Description
1 +24V Pump Internal +24V
2 Clean Digital output
3 Pump on Digital output
4 Pressure value Analogue input