I/O Description
DO COMMON 0-3 Connect to +24V IO
or external +24 V
(not at the same time)
DO COMMON 4-7 Connect to +24V IO
or external +24 V
(not at the same time)
DO 0-7 The outputs will be connected to the external +24 V
when activated.
DI 0-11 The inputs will be activated by a +24 V signal applied
to the input pin.
DI COMMON 0-5 Connect to GND
or external 0 V.
DI COMMON 6-11 Connect to GND
or external 0 V.
GND Ground
NPN mode
I/O Description
+24V IO +24V output
DO COMMON 0-3 Connect to GND
or external 0 V.
DO COMMON 4-7 Connect to GND
or external 0 V.
DO 0-7 The outputs will be connected to the external 0 V
when activated.
DI 0-11 The inputs will be activated by a 0 V signal applied to
the input pin.