TPS Control EN User guide
© Atlas Copco Industrial Technique AB - 9836 5819 01
35
Input configuration
Parameter name Description Range/Values
OK tool 1/ Signal
clutch 1
OK tool 1:
Valid for tool model = electrical
Sets an external signal for an OK message from the
tool controller.
Signal clutch 1:
Valid for tool model = air tool
Used as clutch sensor input with the air tool.
Note that if changing between electrical and pneu-
matic tools in parameter tool model, the setting for
this parameter still remains the same. Make sure to
change the value according to the correct input config-
uration for the tool in question.
---, IN-1-IN-10
Default: IN-2
NOK tool 1/ Signal
trigger 1
NOK tool 1:
Valid for tool model = electrical
Sets an external signal for NOK message from Tool 1
controller.
Signal trigger 1:
Valid for tool model = air tool
Used as trigger sensor input with the air tool (Tool 1)
Note that if changing between electrical and pneu-
matic tools in parameter tool model, the setting for
this parameter still remains the same. Make sure to
change the value according to the correct input config-
uration for the tool in question.
---, IN-1-IN-10
Default: IN-1
Clamp closed Sets an external signal for confirmation when clamping
is engaged
---, IN-1-IN-10
Default: ---
External start Sets an external input signal to start. If set, the corre-
sponding keys will be deactivated on the keyboard.
---, IN-1-IN-10
Default: ---
External reset Sets an external reset input.
If set, the corresponding keys are deactivated on the
keyboard. A high-level signal for this input results in
the cancellation of a currently-processing job.
---, IN-1-IN-10
Default: ---
External repeat Sets an external input for the Repeat/Back function.
If this digital input is set, the corresponding button on
the TPS keyboard is deactivated.
The back function only applicable if Enable Backstep =
On in the Sequence menu.
---, IN-1-IN-10
Default: ---
External NOK ackn. Sets an external input for the NOK Acknowledge func-
tion.
If this input is set, the corresponding button on the
TPS keyboard is deactivated.
Only applicable if NOK acknowledge = Yes in the Se-
quence menu
---, IN-1-IN-10
Default: ---