- 34 -
OPERATIONS OVERVIEW
During operation
Regularly carry out following
checks:
1. That the regulating valve (RV) is
correctly adjusted, i.e. starts decreasing
the engine speed when reaching the
preset working pressure in the receiver.
2. Check the air outlet temperature of the
compressor element.
3. Check the engine oil pressure, the
coolant temperature and display of
control panel.
4. Avoid the engine running out of fuel.
Nevertheless, if this happens, fill the
fuel tank and prime the fuel system to
speed up starting (see section Specific
start procedure).
SPECIFIC START PROCEDURE
Follow this start procedure when the
compressor is put in operation for the first
time and after running out of fuel or
changing the fuel filter.
Loosen the vent screw (1) on the fuel
filter.
Operate the hand pump (2) until fuel
comes out of the bore for the vent screw,
and air is completely removed from the
fuel system.
Fasten the vent screw (1).
Switch the “ON/OFF” switch to
position ”ON”. The instrument panel
will now perform a brief selftest.
Push the start button and the starter
motor will automatically try to start the
engine.
When the engine is running, the
air outlet valves (ball valves)
must always be put in fully
opened or fully closed position.
The doors must be closed during
operation and may be opened
for short periods for inspection
and adjustments only.
After cleaning /draining the fuel
tanks, the system is filled with
air.
Before starting the engine
operate the fuelpump on the
fuelfilter to fill the fuelsystem.
When under pressure the engine
will start after approximately 10
seconds. If the system is not
under pressure, it will take a few
minutes untill the engine will
start.