25
• Consider the braking or stopping distances according to the movement speed. Reduce speed
when moving on slopes (platform lowered).
• It is recommended to wear protective equipment.
2.4 ELECTROCUTION HAZARDS
• This machine is not insulated and does not offer any
protection when near or in contact with an electric current.
• Maintain a minimum safety distance in relation to electric
lines (insulated or otherwise) or powered devices. The
minimum distances indicated in the table below are provided
for information purposes. Regulations specific to the country
or site where the machine is used may require greater safety
distances.
• Take the movements of the machine into account as well as
the possible sway of the electric lines.
• Never raise the platform during a storm or lightning.
Phase to phase
voltage
Minimum safe
distance
0 - 300 V
Avoid contact
300 V - 50 KV
3.05 meters
50 KV - 200 KV
4.60 meters
200 KV - 350 KV
6.10 meters
350 KV - 500 KV
7.62 meters
500 KV - 750 KV
10.67 meters
750 KV - 1000 KV
13.72 meters
DANGER
NEVER MOVE THE MACHINE OR MOVE PERSONNEL NEAR ELECTRICAL CABLES
OR EQUIPMENT.
ALWAYS ASSUME THAT THE ELECTRICAL CABLES OR APPLIANCES ARE LIVE
UNLESS YOU ARE SURE THAT THE POWER HAS BEEN CUT OFF.
PERSONNEL ON THE GROUND MUST KEEP AWAY IF THE MACHINE IS BEING USED
NEAR ELECTRIC LINES OR POWERED EQUIPMENT.
IN THE EVENT OF CONTACT WITH AN ELECTRIC LINE OR POWERED APPLIANCE,
PERSONNEL ON THE GROUND MUST KEEP AWAY FROM THE MACHINE UNTIL THE